View Full Version : EON Power 15 blows 4a fuse on contact.
SMKSoundPro
02-04-2009, 09:10 PM
Dear Friends, The Eon power 15 I use for a booth monitor popped its main fuse and one more I put in. Wht do I do next? Just replace the Amp?
Any help is appreciated!
Does anyone do EON repair, and/ or could help a guy?
Scotty.
edgewound
02-04-2009, 09:14 PM
Dear Friends, The Eon power 15 I use for a booth monitor popped its main fuse and one more I put in. Wht do I do next? Just replace the Amp?
Any help is appreciated!
Does anyone do EON repair, and/ or could help a guy?
Scotty.
Yes....replace the amp. I might have one in stock. Probably took out the HF driver too.
I can talk to you more about it tomorrow.
SMKSoundPro
02-04-2009, 11:14 PM
Thanks Edge!
Its a grey Eon gen 1. Just the b-flat basic Eon.
Just checked the 2418 and it is good. Swept the woof and it is good, also.
Put in a new fuse and applied line voltage to the power transformer with a variac and saw 60v across the whole secondary and 30vac across the ends and the center tap, so I believe that is fine.
scotty.
SMKSoundPro
02-06-2009, 12:02 AM
Thanks Edge!
It was great to talk with you today!
Scotty.
Powered by vBulletin® Version 4.2.5 Copyright © 2024 vBulletin Solutions Inc. All rights reserved.